Background: Philosplates are pre-shaped and pre-contoured locking compression plates, with an aiming device for insertion of the locking screws and positioning of the plate to prevent impingement in displaced surgical neck humerus fracture. The aim of the study was to evaluate treatment outcome of extraarticular 2-part, displaced surgical neck humerus fractures (AO 11A3) in patients by philos plate.
Method: This study was carried out to evaluate the treatment outcome of PHILOS plate fixation for extraarticular 2-part, displaced surgical neck humerus fractures (AO 11A3) in 19 consecutive patients.15 men and 4 women aged 22 to 59 (mean, 39) years underwent PHILOS plate fixation for extraarticular 2-part, displaced surgical neck humerus fractures (AO 11A3). All fractures were closed with no associated injuries. Patients were assessed radiologically and functionally using the Constant shoulder score. Patients were followed up for 5 to 24 (mean, 11) months.
Results: 18 fractures united. In one case there was infected nonunion with implant failure. The mean Constant shoulder score was 72 (range, 30–89).10 patients had a score exceeding 75, 8 were scored between 50 and 75, and 1 was below 50.
Conclusion: PHILOS plate fixation provided stable fixation, minimal metal work problems and enabled early range-of-motion exercises to achieve acceptable functional results.