Background: Ultrasound is the best and safest modality to obtain information about the fetus and its environment directly and it is an accurate method for determining the gestational age. It has been postulated that each population should use their own normograms because of the interpopulation differences in the ultrasound measurements.
Objectives: This study was designed to correlate the abdominal circumference with gestational age by using real time ultrasonogram in Bangladeshi population and also comparison with other established obstetrical chart/table.
Methods: A comparative descriptive study was carried out in the department of radiology and imaging BIRDEM, during the period of June 2005 to May 2006 on three methods. In this study gestational age was determined on the basis of abdominal circumference and a correlation was established between weeks of gestation calculated from LMP and estimated gestational age which measured from Hadlock, Campbell and Tokyo chart or tables.
Results: A strong positive significant correlation was found between menstrual age and predicted gestational age measured from the AC in Hadlock chart (r=0.9968, p<0.001), in Campbell chart (r=0.9966, p<0.001) and in Tokyo chart (r=0.9926, p<0.001).
Conclusions: It has been postulated that each population should use their own normograms because of the inter population differences in the ultrasound measurements.